106 Key features

 

  • Voltage, resistance, continuity, capacitance
  • Input terminal for ac and dc current measurements to 10 A and current
  • Data hold

 

The Fluke 106 digital multimeter is made to fit the way you work! It is designed to fit in the palm of your hand and go with you no matter where your job takes you.

 

 

107 Key features

 

  • Voltage, resistance, continuity, capacitance
  • Input terminal for ac and dc current measurements to 10 A and current
  • Backlit display
  • Data hold
  • Diode test, plus frequency and duty cycle measurements

 

The Fluke 107 digital multimeter is made to fit the way you work! It is designed to fit in the palm of your hand and go with you no matter where your job takes you.

 

Fluke 106/107 Palm-sized Digital Multimeter

Model
  • Accuracy Specifications      
    Function Range Resolution Accuracy
    AC Volts 6.000 V 0.001 V 1.0 % + 3
    (40 Hz to 500Hz)1 60.00 V 0.01 V 1.0 % + 3
      600.0 V 0.1 V 1.0 % + 3
    DC Volts 6.000 V 0.001 V 0.5 % + 3
      60.00 V 0.01 V 0.5 % + 3
      600.0 V 0.1 V 0.5 % + 3
    AC Millivolts 600.0 mV 0.1 mV 3.0 % + 3
    Diode Test2 2.000 V 0.001 V 10%
    Resistance 400.0 Ω 0.1 Ω 0.5 % + 3
    (Ohms) 4.000 kΩ 0.001 kΩ 0.5 % + 2
      40.00 kΩ 0.01 kΩ 0.5 % + 2
      400.0 kΩ 0.1 kΩ 0.5 % + 2
      4.000 MΩ 0.001 MΩ 0.5 % + 2
      40.00 MΩ 0.01 MΩ 1.5% + 3
    Capacitance3 50.00 nF 0.01 nF 2 % + 5
      500.0 nF 0.1 nF 2 % + 5
      5.000 μF 0.001 μF 5 % + 5
      50.00 μF 0.01 μF 5 % + 5
      500.0 μF 0.1 μF 5 % + 5
      1000 μF 1 μF 5 % + 5
    Frequency4 Hz 50.00 Hz 0.01 Hz NA
    (10 Hz – 100 kHz) 500.0 Hz 0.1 Hz  
      5.000 kHz 0.001 kHz  
      50.00 kHz 0.01 kHz  
      100.0 kHz 0.1 kHz  
    Duty Cycle4 1 % to 99 % 0.10% NA
    AC Current 4.000 A 0.001 A 1.5 % + 3
    (40 Hz to 200 Hz) 10.00 A 0.01 A  
    DC Current 4.000 A 0.001 A 1.5 % + 3
      10.00 A 0.01 A  

     

    • All AC, Hz, and duty cycle are specified from 1 % to 100 % of range. Inputs below 1 % of range are not specified.
    • Typically, open circuit test voltage is 2.0 V and short circuit current is <0.6 mA.
    • Specifications do not include errors due to test lead capacitance and capacitance floor (may be up to 1.5 nF in the 50 nF range).
    • All AC, Hz, and duty cycle are specified from 1 % to 100 % of range. Inputs below 1 % of range are not specified.

     

    Function Overload Protection Input Impedance (Nominal) Common Mode Rejection Ratio Normal Mode Rejection Ratio
    AC Volts 600 V 1 >10 MΩ <100 pF 2 >60 dB at dc,
          50 Hz or 60 Hz  
    \AC Millivolts 600 mV >1M, <100 pF >80 dB at 50 Hz or 60 Hz
    DC Volts 600 V 1 >10 MΩ <100 pF >100 dB at dc, >60 dB at 50 Hz or 60 Hz
          50 Hz or 60 Hz  

     

    • 6 x 105 V Hz Max
    • For mV (AC), input impedance is approximately 1 MΩ.

     

    General Specifications  
    Maximum Voltage Between any Terminal and Earth Ground 600 V
    Display (LCD) 6000 counts, updates 3/sec
    Battery Type 2 AAA, NEDA 24A, IEC LR03
    Battery Life 200 hours minimum
    Temperature  
    Operating 0 °C to 40 °C
    Storage -30 °C to 60 °C
    Relative Humidity  
    Operating Humidity Non-condensing when <10°C
      ≤90 % at 10 °C to 30 °C; ≤75 % at 30 °C to 40 °C
    Operating Humidity, 40 MΩ Range ≤80 % at 10 °C to 30 °C; ≤70 % at 30 °C to 40 °C
    Altitude  
    Operating 2000 m
    Storage 12,000 m
    Temperature Coefficient 0.1 X (specified accuracy) /°C (<18 °C or >28 °C)
    Fuse Protection for Current Inputs 11A, 1000V Fast Fuse, Fluke specified part only
    Size (HxWxL) 142 mm x 69 mm x 28mm
    Weight 200 g
    IP Rating IEC 60529: IP 40
    Safety IEC 61010-1: 600 V CAT III, Pollution Degree 2
    Electromagnetic Environment IEC 61326-1: Portable
    Electromagnetic Compatibility Applies to use the Korea only. Class A Equipment (Industrial Broadcasting and Communication Equipment)1
    • This product meets requirements for industrial (Class A) electromagnetic wave equipment and seller or user should take notice of it. This equipment is intended for use in business environments and is not to be used in homes.

©2019 BY DELTA NETWORK SYSTEMS HONG KONG LIMITED

  • Facebook - Grey Circle
  • Instagram - Grey Circle
  • LinkedIn - Grey Circle